Shop - Dubai/ Qatar/ Saudi Arabia/ Oman/ Kuwait – Hotline Trading LLC https://hotlinetradingllc.com Fri, 02 Aug 2024 13:19:27 +0000 en-US hourly 1 https://wordpress.org/?v=6.8.1 Air Separators & Expansion Tanks https://hotlinetradingllc.com/product/air-separator-and-expansion-tanks/ Sun, 10 Aug 2014 11:13:26 +0000 https://hotlinetradingllc.com/?post_type=product&p=1289 Designed, constructed, and tested per ASME section VIII, Division 1 standards.

Expansion Tanks

The proper application of both the pressurization (EXTROL Expansion Tanks) and air elimination (AMTROL Tangential Air Separator) devices will solve your "System Air" problems. These key components are necessary in the design and construction of closed circulation systems.

AX Series Extrol (Horizontal & Vertical Models)

  • Proven Diaphram design since 1954
  • Designed and constructed per ASME Section VIII, Division 1 Standards
  •  Horizontal models are available with optional saddles
  • Factory pre-charged to 12 psig (0.83 bar)
  • Available working pressure : 125psig (8.6 bar) and 150 psig (10 bar)
  • Maximum operating temperature is 240 deg F (115 deg C)

L Series Extrol

  • Replaceable bladder design
  • Designed and constructed per ASME Section VIII, Division 1 Standards
  •  Free-standing on integral floor stands
  • Easily installed
  • Factory pre-charged to 12 psig (0.83 bar)
  • Available working pressure : 125psig (8.6 bar) , 150 psig (10 bar), 175psig (12 bar) and 250 psig (17bar)
  • Maximum operating temperature is 240 deg F (115 deg C)
  • Maximum operating temperature is 240 deg F (115 deg C)

 LBC Series Extrol

The LBC bottom connection bladder series incorporates a partial acceptance replaceable bladder made of a heavy duty butyl material. The seamless bladder construction and contoured bladder design ensures repeatable and predictable long-life expectancy.

  • Designed and constructed per ASME Section VIII, Division 1 Standards
  • Replaceable bladder design
  • Factory pre-charged to 12 psig (0.83 bar)
  • Available working pressure : 125psig (8.6 bar) and 150 psig (10 bar)
  • Maximum operating temperature is 240 deg F (115 deg C)
  • broad range of sizes from 10gal. (35lit to 158 gal. (600Lit.)
  • Available with optional seismic restraints and site glass.
https://www.precisionstoragevessels.com/
Precision Expansion Tank Catalogue

Tangential Air Separators

The AMTROL line of tangential air separators are ASME vessels designed with tangential openings to create a low-velocity vortex where entrained air is separated and removed from circulating water or anti-freeze in a closed system. In addition, these tangential air separators can be supplied with a stainless steel strainer to collect unwanted system debris.

AMTROL tangential air separators are ideally suited to help eliminate problems often associated with trapped system air such as blocked terminal units, inefficient pump operation and performance, and costly corrosion and fouling of equipment.

Material Construction

  • Steel - ANSI 150# flange construction
  • All Steel body Construction
  • Stainless steel strainer

Features

  • Designed and constructed per ASME Section VIII, Division 1 Standards
  • 1 to 24 inch standards
  • Tangential design with low velocity vortex action
  • Flanged or grooved pipe connectors
  • Removable, stainless steel strainer available
  • Blow down connection to enable cleaning of unit and strainer
  • NPT vent connection
  • Maximum working pressure : 125psig (8.6 bar) and 150 psig (10 bar)
  • Maximum operating temperature is 350 deg F (177 deg C)
https://www.amtrol.com/
Tangential Air Separator Catalogue

Rephrase with Ginger (Ctrl+Alt+E)

The post Shop first appeared on Dubai/ Qatar/ Saudi Arabia/ Oman/ Kuwait – Hotline Trading LLC.

]]>
Designed, constructed, and tested per ASME section VIII, Division 1 standards.

Expansion Tanks

The proper application of both the pressurization (EXTROL Expansion Tanks) and air elimination (AMTROL Tangential Air Separator) devices will solve your "System Air" problems. These key components are necessary in the design and construction of closed circulation systems.

AX Series Extrol (Horizontal & Vertical Models)

  • Proven Diaphram design since 1954
  • Designed and constructed per ASME Section VIII, Division 1 Standards
  •  Horizontal models are available with optional saddles
  • Factory pre-charged to 12 psig (0.83 bar)
  • Available working pressure : 125psig (8.6 bar) and 150 psig (10 bar)
  • Maximum operating temperature is 240 deg F (115 deg C)

L Series Extrol

  • Replaceable bladder design
  • Designed and constructed per ASME Section VIII, Division 1 Standards
  •  Free-standing on integral floor stands
  • Easily installed
  • Factory pre-charged to 12 psig (0.83 bar)
  • Available working pressure : 125psig (8.6 bar) , 150 psig (10 bar), 175psig (12 bar) and 250 psig (17bar)
  • Maximum operating temperature is 240 deg F (115 deg C)
  • Maximum operating temperature is 240 deg F (115 deg C)

 LBC Series Extrol

The LBC bottom connection bladder series incorporates a partial acceptance replaceable bladder made of a heavy duty butyl material. The seamless bladder construction and contoured bladder design ensures repeatable and predictable long-life expectancy.

  • Designed and constructed per ASME Section VIII, Division 1 Standards
  • Replaceable bladder design
  • Factory pre-charged to 12 psig (0.83 bar)
  • Available working pressure : 125psig (8.6 bar) and 150 psig (10 bar)
  • Maximum operating temperature is 240 deg F (115 deg C)
  • broad range of sizes from 10gal. (35lit to 158 gal. (600Lit.)
  • Available with optional seismic restraints and site glass.
https://www.precisionstoragevessels.com/
Precision Expansion Tank Catalogue

Tangential Air Separators

The AMTROL line of tangential air separators are ASME vessels designed with tangential openings to create a low-velocity vortex where entrained air is separated and removed from circulating water or anti-freeze in a closed system. In addition, these tangential air separators can be supplied with a stainless steel strainer to collect unwanted system debris.

AMTROL tangential air separators are ideally suited to help eliminate problems often associated with trapped system air such as blocked terminal units, inefficient pump operation and performance, and costly corrosion and fouling of equipment.

Material Construction

  • Steel - ANSI 150# flange construction
  • All Steel body Construction
  • Stainless steel strainer

Features

  • Designed and constructed per ASME Section VIII, Division 1 Standards
  • 1 to 24 inch standards
  • Tangential design with low velocity vortex action
  • Flanged or grooved pipe connectors
  • Removable, stainless steel strainer available
  • Blow down connection to enable cleaning of unit and strainer
  • NPT vent connection
  • Maximum working pressure : 125psig (8.6 bar) and 150 psig (10 bar)
  • Maximum operating temperature is 350 deg F (177 deg C)
https://www.amtrol.com/
Tangential Air Separator Catalogue

Rephrase with Ginger (Ctrl+Alt+E)

The post Shop first appeared on Dubai/ Qatar/ Saudi Arabia/ Oman/ Kuwait – Hotline Trading LLC.

]]>
Chilled Water Buffer Tanks https://hotlinetradingllc.com/product/chilled-water-buffer-tanks-air-receivers/ Sat, 09 Aug 2014 11:22:43 +0000 https://hotlinetradingllc.com/?post_type=product&p=1294 Chilled Water Buffer Tanks

Chilled water buffer tanks are designed, to be used with chillers which do not have sufficient water volumes as required by the chiller.

Chillers are designed to operate with a minimum water volume, which typically ranges from 22 litre to 38 litres per ton for air conditioning application, for to get better temperature accuracy.

Most of the chiller compressors can only start 3 to 4 times per hour. If the compressor is off and if there is a demand for chilled water the compressor cannot get on immediately.

Without chilled water, the building will not get the required cooling. To solve this problem chilled water buffer vessels are added in the system. These tanks increase the capacity of the chilled water in the system and stabilize the return.

• Tank manufactured as per ASME Standard

• Ring supports

• Internal Baffle

• Air vent

• Insulation and cladding (optional)

• Material A36 (other materials consult factory)

• Flanged connection (inlet and outlet)

• Manhole (optional)

• Tank will be externally sandblasted to SA 2.5 and then coated with two coats of red oxide primer.

• Horizontal configuration also available .

• Manufacturers' data report for pressure vessels from U-1A as required by the provisions of the ASME code will be furnished for each

chilled water buffer tank.

• Standard working pressure 10 bar, Test pressure 15 bar.

• Plate Thickness are in excess to relevant codes.

 

https://www.precisionstoragevessels.com/
Chilled Water Buffer Tank Catalogue

The post Shop first appeared on Dubai/ Qatar/ Saudi Arabia/ Oman/ Kuwait – Hotline Trading LLC.

]]>
Chilled Water Buffer Tanks

Chilled water buffer tanks are designed, to be used with chillers which do not have sufficient water volumes as required by the chiller.

Chillers are designed to operate with a minimum water volume, which typically ranges from 22 litre to 38 litres per ton for air conditioning application, for to get better temperature accuracy.

Most of the chiller compressors can only start 3 to 4 times per hour. If the compressor is off and if there is a demand for chilled water the compressor cannot get on immediately.

Without chilled water, the building will not get the required cooling. To solve this problem chilled water buffer vessels are added in the system. These tanks increase the capacity of the chilled water in the system and stabilize the return.

• Tank manufactured as per ASME Standard

• Ring supports

• Internal Baffle

• Air vent

• Insulation and cladding (optional)

• Material A36 (other materials consult factory)

• Flanged connection (inlet and outlet)

• Manhole (optional)

• Tank will be externally sandblasted to SA 2.5 and then coated with two coats of red oxide primer.

• Horizontal configuration also available .

• Manufacturers' data report for pressure vessels from U-1A as required by the provisions of the ASME code will be furnished for each

chilled water buffer tank.

• Standard working pressure 10 bar, Test pressure 15 bar.

• Plate Thickness are in excess to relevant codes.

 

https://www.precisionstoragevessels.com/
Chilled Water Buffer Tank Catalogue

The post Shop first appeared on Dubai/ Qatar/ Saudi Arabia/ Oman/ Kuwait – Hotline Trading LLC.

]]>