Shop - Dubai/ Qatar/ Saudi Arabia/ Oman/ Kuwait – Hotline Trading LLC https://hotlinetradingllc.com Thu, 01 Aug 2024 07:45:09 +0000 en-US hourly 1 https://wordpress.org/?v=6.8.1 Burners https://hotlinetradingllc.com/product/burners/ Sun, 21 Sep 2014 08:05:15 +0000 https://hotlinetradingllc.com/?post_type=product&p=1585

 OIL FIRED BURNERS

BENTONE B30-2, 4.5 -1 7 Kg/hr (53-202KW)

BENTONE B65, 24 - 99 Kg/hr (285-1174KW)

BENTONE B80, 50 - 214 Kg/hr (593-2538KW)

  • Energy Saving and compatible with environmental requirements
  • Quiet in operation and designed for easy maintenance
  • Reliable and trouble - free
  • Designed and approved in accordance with the European Standard EN267
  • Suitable for high resistance boilers
  • Industry standard components easily available
  • Designed for on / off and high/low operation
  • Plug-in contact facilities the installation
  • With hydraulic air adjustment
  • Fuel - Light distllate oil Class D (1.5-5.5 cSt@40°C)

GAS FIRED BURNER

BENTONE BG300-2 (60-190 KW)

BENTONE BG650 (200-1125 KW)

  • Energy saving and compatiable with environmental requirements
  • Quiet in operation and designed for easy maintenance
  • Designed and approvaed in accordance with the European Standard EN676
  • Plug - in contact facilities the installation
  • Hinged flange
  • Designed for one stage, two stage, or modulating operation
  • Available for natural gas, LPG, town gas, biogas

http://www.bentone.com

The post Shop first appeared on Dubai/ Qatar/ Saudi Arabia/ Oman/ Kuwait – Hotline Trading LLC.

]]>

 OIL FIRED BURNERS

BENTONE B30-2, 4.5 -1 7 Kg/hr (53-202KW)

BENTONE B65, 24 - 99 Kg/hr (285-1174KW)

BENTONE B80, 50 - 214 Kg/hr (593-2538KW)

  • Energy Saving and compatible with environmental requirements
  • Quiet in operation and designed for easy maintenance
  • Reliable and trouble - free
  • Designed and approved in accordance with the European Standard EN267
  • Suitable for high resistance boilers
  • Industry standard components easily available
  • Designed for on / off and high/low operation
  • Plug-in contact facilities the installation
  • With hydraulic air adjustment
  • Fuel - Light distllate oil Class D (1.5-5.5 cSt@40°C)

GAS FIRED BURNER

BENTONE BG300-2 (60-190 KW)

BENTONE BG650 (200-1125 KW)

  • Energy saving and compatiable with environmental requirements
  • Quiet in operation and designed for easy maintenance
  • Designed and approvaed in accordance with the European Standard EN676
  • Plug - in contact facilities the installation
  • Hinged flange
  • Designed for one stage, two stage, or modulating operation
  • Available for natural gas, LPG, town gas, biogas

http://www.bentone.com

The post Shop first appeared on Dubai/ Qatar/ Saudi Arabia/ Oman/ Kuwait – Hotline Trading LLC.

]]>
Oil / Gas Fired Water Heaters https://hotlinetradingllc.com/product/oil-fired-water-heaters/ Wed, 20 Aug 2014 10:58:56 +0000 https://hotlinetradingllc.com/?post_type=product&p=1251 Oil / Gas Fired Water Heaters

Direct Oil / Gas Fired water heaters are the best solution where fuel fired hot water system can be used. Wide range output can be achieved in this water heaters. Fully automatic burners are used for safe operation.

Advantages

  • Efficiency is maintained throughout the range of load.Even at part load all energy is converted into heat.
  • Space requirements are minimum.
  • Separate boiler not required.
  • Installation is simplified.
  • The calorifier can be installed with minimum electric load.
  • Maintenance is kept to a minimum.
  • Low nox burners are used.
  • Fuel efficient burners are used.
  • Diesel oil, Natural Gas, LPG and Propane can be used.
  • Can also be used with solar or heat pump system where oil or gas fired system can be considered as a backup.

Water heaters are fitted with removable type fire tube heat exchanger. These heat exchangers are made of carbon steel tubes and coated with specially formulated coating material to withstand high temperature.

Burner

Mono block pressure jet fully automatic oil / gas fired burners are used to heat the water. Depend on recovery, burners can be selected either on / off type or full modulation type. Burners will be highlyfuel efficient and with low nox capabilities.

Gas Fired Burner

  • Energy Saving and compatible with environmental requirements
  • Quiet in operation and designed for easy maintenance
  • Designed and approvaed in accordance with the European Standard EN676
  • Plug – in contact facilities the installation
  • Hinged flange
  • Designed for one stage, two stage, or modulating operation
  • Available for natural gas, LPG, town gas, biogas.

Oil Fired Burner

  • Energy Saving and compatible with environmental requirements
  • Quiet in operation and designed for easy maintenance
  • Reliable and trouble – free
  • Designed and approved in accordance with the European Standard EN267
  • Suitable for high resistance boilers
  • Industry standard components easily available
  • Designed for on / off and high/low operation
  • Plug-in contact facilities the installation
  • With hydraulic air adjustment
  • Fuel – Light distllate oil Class D (1.5-5.5 cSt@40°C)

 

 

 

The post Shop first appeared on Dubai/ Qatar/ Saudi Arabia/ Oman/ Kuwait – Hotline Trading LLC.

]]>
Oil / Gas Fired Water Heaters

Direct Oil / Gas Fired water heaters are the best solution where fuel fired hot water system can be used. Wide range output can be achieved in this water heaters. Fully automatic burners are used for safe operation.

Advantages

  • Efficiency is maintained throughout the range of load.Even at part load all energy is converted into heat.
  • Space requirements are minimum.
  • Separate boiler not required.
  • Installation is simplified.
  • The calorifier can be installed with minimum electric load.
  • Maintenance is kept to a minimum.
  • Low nox burners are used.
  • Fuel efficient burners are used.
  • Diesel oil, Natural Gas, LPG and Propane can be used.
  • Can also be used with solar or heat pump system where oil or gas fired system can be considered as a backup.

Water heaters are fitted with removable type fire tube heat exchanger. These heat exchangers are made of carbon steel tubes and coated with specially formulated coating material to withstand high temperature.

Burner

Mono block pressure jet fully automatic oil / gas fired burners are used to heat the water. Depend on recovery, burners can be selected either on / off type or full modulation type. Burners will be highlyfuel efficient and with low nox capabilities.

Gas Fired Burner

  • Energy Saving and compatible with environmental requirements
  • Quiet in operation and designed for easy maintenance
  • Designed and approvaed in accordance with the European Standard EN676
  • Plug – in contact facilities the installation
  • Hinged flange
  • Designed for one stage, two stage, or modulating operation
  • Available for natural gas, LPG, town gas, biogas.

Oil Fired Burner

  • Energy Saving and compatible with environmental requirements
  • Quiet in operation and designed for easy maintenance
  • Reliable and trouble – free
  • Designed and approved in accordance with the European Standard EN267
  • Suitable for high resistance boilers
  • Industry standard components easily available
  • Designed for on / off and high/low operation
  • Plug-in contact facilities the installation
  • With hydraulic air adjustment
  • Fuel – Light distllate oil Class D (1.5-5.5 cSt@40°C)

 

 

 

The post Shop first appeared on Dubai/ Qatar/ Saudi Arabia/ Oman/ Kuwait – Hotline Trading LLC.

]]>
Solar Hot Water System https://hotlinetradingllc.com/product/solar-hot-water-system/ Sun, 21 Sep 2014 07:35:48 +0000 https://hotlinetradingllc.com/?post_type=product&p=1581 SELECTIVE FLAT COLLECTORS

Selective treatment, to increase absorption of solar radiation High transparency, low iron content glass anodized aluminum frame, available support structures at different angles

EVO 2500

The selective flat plate collector EVO 2500 (2,5 sqm) is available in its horizontal variant, which allows to reduce the

vertical dimension, eliminating in some cases the aesthetic impact of the installation.

WATER HEATER INTEGRATION KIT

Integration with boilers for DHW, Automated management of the system, without electronic devices Compactness and ease of installation.

The insulated hydraulic group SolarKIT allows the integration of solar systems and boilers with DHW production and is composed of thermostatic diverting valve and anti-scald mixer, all housed in a single insulated casing for easy installation.

CIRCULATION UNIT

Full integration of the circulation, control, security and loading devices for forced circulation systems Available in 4 versions, for all system requirements 3-speed solar pump, Flow meter/regulator with loading and unloading system valves.

Features common to single way and two ways units:

• Fully insulated box;

• Meter/flow-rate regulator with valves for loading and unloading of the system;

• Solar pump with cable gland;

• 3-ways flanged ball valve DN20 with check valve 10 mbar (the check valve can be switched off by rotating the handle 45°) with handle for termometer

(blue ring termometer; 0÷120 °C);

• Safety group 6 bar with pressure gauge Ø50 mm 0-10 bar with connection ¾” male for the expansion tank;

• Axis-to-axis distance 125 mm. Insulation box in EPP;

• Special metal back plate that secures the isolation and allows for easy installation both to the wall and to the tank;

• PN 10. Continue temperature 120°C; (short-pediod: 120°C per 20 s);

• Male threaded connections.

Furthermore, the two-way versions feature:

• Flanged ball valve DN20 with check valve 10 mbar (the check valve can be switched off by rotating the handle 45°) with handle for thermometer (red

ring thermometer; 0°C÷120°C);

• Connection and fitting tube.

 FORCED CIRCULATION SYSTEMS

The forced circulation system involves the use of a low-pressure pump (circulation group or circulator) for the handling of the heat transfer fluid, so as to implement the heat transfer from the collector to the tank. A differential temperature control unit provides for activating and deactivating the circulation group, depending on the need and the amount of solar radiation available.

Our Brands :  SOLAR HOT WATER SYSTEM in dubaiSOLAR HOT WATER SYSTEM in dubai

The post Shop first appeared on Dubai/ Qatar/ Saudi Arabia/ Oman/ Kuwait – Hotline Trading LLC.

]]>
SELECTIVE FLAT COLLECTORS

Selective treatment, to increase absorption of solar radiation High transparency, low iron content glass anodized aluminum frame, available support structures at different angles

EVO 2500

The selective flat plate collector EVO 2500 (2,5 sqm) is available in its horizontal variant, which allows to reduce the

vertical dimension, eliminating in some cases the aesthetic impact of the installation.

WATER HEATER INTEGRATION KIT

Integration with boilers for DHW, Automated management of the system, without electronic devices Compactness and ease of installation.

The insulated hydraulic group SolarKIT allows the integration of solar systems and boilers with DHW production and is composed of thermostatic diverting valve and anti-scald mixer, all housed in a single insulated casing for easy installation.

CIRCULATION UNIT

Full integration of the circulation, control, security and loading devices for forced circulation systems Available in 4 versions, for all system requirements 3-speed solar pump, Flow meter/regulator with loading and unloading system valves.

Features common to single way and two ways units:

• Fully insulated box;

• Meter/flow-rate regulator with valves for loading and unloading of the system;

• Solar pump with cable gland;

• 3-ways flanged ball valve DN20 with check valve 10 mbar (the check valve can be switched off by rotating the handle 45°) with handle for termometer

(blue ring termometer; 0÷120 °C);

• Safety group 6 bar with pressure gauge Ø50 mm 0-10 bar with connection ¾” male for the expansion tank;

• Axis-to-axis distance 125 mm. Insulation box in EPP;

• Special metal back plate that secures the isolation and allows for easy installation both to the wall and to the tank;

• PN 10. Continue temperature 120°C; (short-pediod: 120°C per 20 s);

• Male threaded connections.

Furthermore, the two-way versions feature:

• Flanged ball valve DN20 with check valve 10 mbar (the check valve can be switched off by rotating the handle 45°) with handle for thermometer (red

ring thermometer; 0°C÷120°C);

• Connection and fitting tube.

 FORCED CIRCULATION SYSTEMS

The forced circulation system involves the use of a low-pressure pump (circulation group or circulator) for the handling of the heat transfer fluid, so as to implement the heat transfer from the collector to the tank. A differential temperature control unit provides for activating and deactivating the circulation group, depending on the need and the amount of solar radiation available.

Our Brands :  SOLAR HOT WATER SYSTEM in dubaiSOLAR HOT WATER SYSTEM in dubai

The post Shop first appeared on Dubai/ Qatar/ Saudi Arabia/ Oman/ Kuwait – Hotline Trading LLC.

]]>